PROGRAMMINGPROCEDURES
SECTION 200-255-307
JANUARY1993
list number
XX.
(XX = 1 - 50.)
NONE-No
list assigned.
WTA (Warning
Tone Allowed?)-Defines
an in-
terruption-protected
station.
An "N" response
will prevent warning
tones from being applied to
the station.
Enter: Y or N.
CFT (Call Forward
to Trunk)-Permits
calls to
this station to be forwarded
over a trunk to an
outside directory
number
(maximum:
16 digits).
Enter: Y or N.
TOL (Toll Restriction
Class)-Assigns
one of the
ten Toll Restriction
classes to the station. Classes
0 - 7 are defined
in the Toll Restriction
Data
Block (DTOL
Program).
Class 8 is simple toll
restriction;
restricting
either 0 or 1 as the first
digit. NONE defines the station as unrestricted.
Enter: 0 - 8 or NONE.
MWL (Message
Waiting
Lamp)-Defines
a sta-
tion that is equipped
with a Message
Waiting
Lamp.
Enter: Y or N.
tinuous
ringing)
when a station
goes off-hook,
but does not complete
dialing
a valid number
before the Line Lockout Timeout
period elapses.
The destination
can be programmed
as either a
specific station, an attendant,
orthe system UNA
device. (In tenant service, the system will route
the RDS call to the assigned
tenant,
when ATT
is entered.)
The designation
of an Emergency
Ringdown
Station
is particularly
important
in
Lodging/Health
Care applications.
Enter: XXXX = l- - 4-digit station number.
ATT = Attendant.
UNA = System
UNA.
NONE = No designation
of Emergency
Ringdown
Station.
OCA (Off-hook
Call Announce)-Defines
whether
this feature
is in automatic
or manual
mode.
When programmed
in auto mode, it allows the
system to announce
an incoming
call when the
station
is off-hook.
If it is in manual
mode, the
system
will let the caller enter an access code
before the call interrupts
the ongoing
conversa-
tion.
Busy tone
must
be heard
(i.e., no call-
forwards)
to activate
this feature.
Enter: A or M.
RDS (Emergency
Ringdown
Station)-Indicates
the destination
for an emergency
signal
(con-
7-14