NEC iPASOLINK EX Advanced Instruction Manual page 535

71-76/81-86 ghz packet radio system
Table of Contents

Advertisement

9-8
Figure 9-8 Information Dialog Box
7. Assign the appropriate value to each parameter:
Figure 9-9 Step 2 PTP Detail Setting Option Window
Parameter
Clock Model
Domain Number
PTP Priority
Priority 1 Value
Priority 2 Value
Local Priority
(Clock) Value
DSCP
PTP Hold Off Time
GGS-000547-01E
Step 2 PTP Detail Setting
Table 9-3
PTP Detail Setting Parameters
Value
PTP Only
0 to 127
(24 to 43)
0 to 255
0 to 255
1 to 255
0 to 63
1 to 86400
Set Equipment Clock and Synchronization
option window appears.
Description
Clock Model is fixed to PTP Only.
Specify PTP Domain Number that should be associated with
that of the opposing site equipment.
 When PTP Profile selects G.8275.1, the available
numbers are limited to 43 from 24 in compliance with
G.8275.1.
Specifies the priority to PTP packet, which should be associ-
ated with that of opposing site equipment.
Specify the DSCP value according to the network configura-
tion to use. This option is voided when Transport Mode
selects PTP over Ethernet.
Specifies the value of Holdoff Timer, which is a period to
release the Holdover state when the PTP function recovers
from the locked state. [unit: second]