5-44
SFP Type Mismatch
This condition indicates that the provided SFP Port type and the mounted SFP
Module do not match.
Procedure 5-32
1.
2.
3.
4.
5.
6.
Speed & Duplex
This condition is not an alarm. The message indicates that the current status of speed
and duplex mode of the indicated port.
SSM Fail
This condition indicates that the received Sync Status Message is in the unstable
condition. The problem of this condition pertains to the input cable or to the external
timing source.
GGS-000548-01E
Launch WebLCT, and display the
configuration. Correct the setting(s) if any inappropriate setting is found.
Retrieve the
Current Status
cleared.
Is the
SFP Type Mismatch
This step ends the procedure.
YES:
Go to Step
4.
NO:
Check if the mounted SFP Module is the correct type for the port.
Is the type of SFP Module appropriate?
Contact NEC.
YES:
Replace SFP Module, and go to Step
NO:
Retrieve the
Current Status
cleared. If the alarm is not cleared, contact NEC for the further maintenance
support.
This step ends the procedure.
Inventory
, and check if the
SFP Type Mismatch
alarm cleared?
6.
, and check if the
SFP Type Mismatch
iPASOLINK EX Advanced: O
CORRECTIVE MAINTENANCE
window to check the port
alarm is
alarm is
Equipment
& M
PERATION
AINTENANCE
ETH
ETH