CONTROL ITEMS
4.9.2.3
NOTE: Proceeding through the following restarts the equipment, which terminates
the WebLCT connection.
Important:
1. Ensure that the data file of FPGA from NEC has already been on the site.
2. Check the F/W versions using the Equipment Inventory Information window.
3. To operate the FPGA data download, the system must be set into the
Maintenance mode; Do not cancel the Maintenance mode while the download
process is in progress.
Procedure 4-24
1. Click the
2. In the
3. Select
Figure 4-126 Update (Storage -> NE) Utility Window
iPASOLINK EX Advanced: O

Update FPGA Data

Maintenance
system into the Maintenance Mode. The
changes to orange.
frame on the left, expand the
MENU
(Storage -> NE) Utility
by clicking its radio button, and then click the
FPGA Data
button.
& M
PERATION
AINTENANCE
tool button on the tool bar of the
. The
Update (Storage -> NE) Utility
Execute tool button
WebLCT
indicator on the tool bar
MAINT
to select
Equipment Utility
window appears.
FPGA Data
GGS-000548-01E
4-79
to put the
Update
tool
Execute