Assign PMON/RMON Settings
4. Assign the appropriate settings, then click the OK button:
Figure 11-6 RMON Threshold Setting Option Window
Parameter
RX Drop Events
RX Undersize Pkts
RX Fragments
RX CRC Alignment
Errors
RX Oversize Pkts
TX Collisions
iPASOLINK EX Adanced: S
Table 11-2 RMON Threshold Setting Parameters
Value
15 minutes
0 to 133929000
1 day
0 to 4294967294
15 minutes
0 to 133929000
1 day
0 to 4294967294
15 minutes
0 to 133929000
1 day
0 to 4294967294
15 minutes
0 to 133929000
1 day
0 to 4294967294
15 minutes
0 to 133929000
1 day
0 to 4294967294
15 minutes
0 to 133929000
1 day
0 to 4294967294
N
S
P
ET
ETWORK AND
YSTEM
Description
Specifies the threshold value to detect an RX Drop
Event condition for a 15-minute period.
Specifies the threshold value to detect an RX Drop
Events condition for a 1-day period.
Specifies the threshold value to detect an RX
Undersize Pkts condition for a 15-minute period.
Specifies the threshold value to detect an RX
Undersize Pkts condition for a 1-day period.
Specifies the threshold value to detect an RX
Fragments condition for a 15-minute period.
Specifies the threshold value to detect an RX
Fragments condition for a 1-day period.
Specifies the threshold value to detect an RX CRC
Alignment Error for a 15-minute period.
Specifies the threshold value to detect an RX CRC
Alignment Error for a 1-day period.
Specifies the threshold value to detect an RX
Oversize Pkts condition for a 15-minute period.
Specifies the threshold value to detect an RX
Oversize Pkts condition for a 1-day period.
Specifies the threshold value to detect a TX
collision for a 15-minute period.
Specifies the threshold value to detect a TX
collision for a 1-day period.