Ipcfl-Set Ipstack Static Parameters; Command Syntax; Description; Defined Values - Huawei MU509 At Command Interface Specification

Hsdpa lga module
Hide thumbs Also See for MU509:
Table of Contents

Advertisement

HUAWEI MU509 HSDPA LGA Module
AT Command Interface Specification
15.10 ^IPCFL–Set IPSTACK Static Parameters

15.10.1 Command Syntax

Command
^IPCFL=<parameter_id>,<value>
^IPCFL?
^IPCFL=?

15.10.2 Description

This command is used to set some parameters of the IPSTACK. It only support set the
value items 5, 10 and 12 now. The other parameters are not supported in currently.
Note:

15.10.3 Defined Values

<parameter_id>: the item which the command will to set.
<value>: the value the command will set the item to.
parameter_id
5
10
12
Issue 04 (2013-01-28)
When used the query command. The response will not contain the unsupported items.
value range (Unit)
1–100 (unit: 0.1s,
default value: 10)
1–1472(unit: 1Byte,
default value: 1024)
0,1(default value: 0)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Internet Service Commands
Possible response(s)
<CR><LF>OK<CR><LF>
In case of an MT-related error:
<CR><LF>ERROR<CR><LF>
<CR><LF>^IPCFL: <parameter_id>,<value>
[<CR><LF>^IPCFL:
<parameter_id>,<value>[...]]<CR><LF>
<CR><LF>OK<CR><LF>
<CR><LF>^IPCFL: <parameter_id>,(list of
supported <value>s),
<CR><LF>^IPCFL: <parameter_id>,(list of
supported <value>s),
...
<CR><LF><CR><LF>OK<CR><LF>
Description
The value of the transparent transmission
timer
The transparent transmission length
Trigger
The transparent transmission mode, see
the command ^IPENTRANS.
207

Advertisement

Table of Contents
loading

Table of Contents