2 COMMUNICATIONS IN AN EMERGENCY
2.9 Placing the Transceiver in Emergency Mode by Using the Activity Detection Function
Using Motion Detection and Stationary Detection Simultaneously (Man-down with
Stationary)
Man-down with Stationary is the function to detect emergency using both the Man-down Detection and Stationary
Detection functions.
If this function is enabled, the transceiver detects emergency using both the Man-down Detection and Stationary
Detection functions. If both Man-down Detection and Stationary Detection enter the detection state, Man-down Delay
Time is activated. If the time configured in Man-down Delay Time elapses while the transceiver continues to be in the state,
the transceiver enters Emergency Mode.
Configuration using KPG-D1/ D1N
Configuring Man-down with Stationary to be enabled or disabled (
Information > Activity Detection)
2.10
Transceiver Behavior When the Transceiver Receives an
Emergency Status
An Alert Tone can sound when the transceiver receives a DMR Emergency Status. This behavior can be configured for
Emergency Status Response.
Refer to
"Emergency Status
DMR FUNC (K, F)/Ver 2.20
Response" for details of Emergency Response.
Transceiver Settings > Emergency > Emergency