6.4

Preparatory steps

Terminate all branches of the wiring system with a connected bus device (e.g., indoor
station, outdoor station, system device).
Do not install the central control system directly next to bell transformers and of other
switched voltage supplies (avoidance of interference).
Do not install the cores of the system bus together with 100 - 240 V cores.
Do not use joint wires for the connecting cables of door openers and wires of the system
bus.
Avoid bridges between different wire types.
Use only two wires for the system bus in a four-core or multi-core cable.
During looping, never install the incoming and outgoing bus within a wire.
Never install the internal and external bus within a conduit.
Product manual 2CKA001473B5343
Connection, installation / mounting
│34