2.5.2 SPEL CT
Backing up/Restoring the Hardware & Manipulator Settings
The system hardware and manipulator configuration data are saved in a backup file that
can be used to restore the whole system.
■ Do not restore the backup data in any other system. The data includes the
original configuration of the system. If the data is restored in the other system,
the system may function improperly or SPEL CT may fail to start up.
If SPLE CT is downgraded and its version is different even though the backup
CAUTION
data is for the same system, an error may occur and the data may fail to be
restored.
Backing up the Hardware & Manipulator Settings
(1) Specify the location, either FD or folder, to back up. Also, be sure that the folder
(2) Close the project.
(3) Select the [Setup] - [Backup] - [System] commands.
(4) Select the folder to backup. Click the <OK> button.
RC520 Rev.7
for the backup file to be saved in is empty since saving a backup of Hardware &
Manipulator settings will delete the other files in the same folder.
If a backup file is to be saved on a floppy disk, be sure that the disk:
has been formatted;
is not write-protected;
is not a system disk.
Click the <New Folder> button when you make a new folder.
Maintenance 2. Regular Maintenance Inspection