Maintenance 4. Control Unit

4.7 Replacing the Fan

To replace the Fan, follow the procedure below:
(1) Shut down Windows. Then, turn OFF the power on both the Control Unit and Drive
Unit.
(2) Remove four screws from the front panel of the Control Unit and remove the fan.
(3) Remove four screws from the fan.
(4) Remove the fan guard from the top of the fan.
Fanguard
Fan
Bottom Plate
(5) Replace the fan with a new one.
(6) Place the new fan and fan guard on the bottom plate. Then, secure them with the
screws.
(7) Secure the fan to the Control
Unit.
RC520 Rev.7