Power Supply; Emergency Connector Plate Kit; Appearance Of Emergency Connector Plate Kit - Epson RC520 Manual

Robot controller
Hide thumbs Also See for RC520:
Table of Contents

Advertisement

Setup & Operation 11. Stand-alone Option for RC520

11.4 Power Supply

■ PC power cable for power source supply from the Drive Unit can not be used
when using the Control Unit only. Use the proper PC power cable conforming
to the specification of the connecting power source.
CAUTION
Ensure that AC power source of the Control Unit meets the following specifications.
Voltage
Frequency
Momentary Power
Interrupt
Power Consumption
Peak Current
Leakage Current

11.5 Emergency Connector Plate Kit

An Emergency Connector Plate Kit is to provide the same function as the emergency
connector of the Drive Unit for the Control Unit.

11.5.1 Appearance of Emergency Connector Plate Kit

The Emergency Connector Plate Kit is connected with MIB as shown below.
MIB
NOTE
The emergency connector board occupies one expansion slot in the Control Unit.
108
Item
: AC100V to AC120V
: AC200V to AC240V
50/60Hz
Less than 10msec.
300W (The monitor is not connected.)
Approximately 40A (at AC200V)
3.5mA max.
Emergency Connector Board
Specification
Emergency Connector
Junction Cable
RC520 Rev.7