External I/O - Panasonic GP-X Series User Manual

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

1.4 External I/O

Output
Analog
output
Input
Power
supply
Ramco Innovations www.ramcoi.com
Terminal
Indication
No.
1
LO
2
GO
3
HI
4
COM
5
ALARM
6
STROBE
7
INT P OUT
8
GND
ANALOG
9
OUT
0 SET
10
11
1
MEMORY
12
2
13
COM
14
TIMING
15
RESET
16
INT P IN
17
0V
18
24V DC
1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18
Name
A signal is output if the measurement
LO output
is smaller than the lower limit value.
A signal is output if the measurement is
GO output
between the upper and lower limit values.
A signal is issued if the measurement
HI output
is larger than the upper limit value.
Common
Common
Alarm output
A signal is output if an error occurs.
An internal trigger outputs for
Strobe output
measurement interval.
A signal is sent to another controller for
Interference
removal of effects caused by interference.
prevention output
Analog ground
The measurement is output in an
analog voltage.
Analog voltage output
The current detection position is forcibly
Zero setting input
zeroed (to become a reference position).
One among four settings is called up
Memory switch 1
from the internal memory to replace
Memory switch 2
the current setting with it.
Common
Common
Timing input
Measurement begins.
Reset input
Temporarily finishes the holding interval.
With a signal sent from another controller,
Interference
effects caused by interference are removed.
prevention input
Power supply 0V
Supply power.
Power supply 24V DC
Phone 800-280-6933 nsales@ramcoi.com
Description
NPN output type: 0V
PNP output type: 24V
NPN output type: 0V
PNP output type: 24V
13