4.4 Display Scale
object from the sensor head is displayed with the factory shipment setting.
With the scaling function, you can arbitrarily change the value displayed ac-
cording to the detected value. A displayed value can be entered at an arbi-
trary distance.
The setting method includes three variations: one-point scaling, two-point
scaling and INV.
Or select the default setting to return to the factory shipment state.
Notice
Note : If the voltage (volts) is selected for the display unit as described
4.4.1 One-Point Scaling
changed. One-point scaling includes a "SLOPE" function with which inclina-
tion changes around the point designated with scaling.
In the case of reverse inclination
Change "0.5mm 0.5000" to "0.5mm 1.5000".
Display
2.0000
0.5000
0
0.5mm
POINT
76
Ramco Innovations www.ramcoi.com
Only the displayed value can be changed with this function. To change the
analog voltage output according to the detected value, use the analog volt-
age output scale.
in section "4.6.2 Selecting the Display Unit" on page 87, the
displayed scale agrees with the voltage output scale. Use the
voltage output scale.
Display
3.0000
2.0000
1.5000
1.0000
0
2mm
If the height detection mode is selected, the inclination becomes negative.
Reverse inclination with "SLOPE".
0.5mm
2mm
Phone 800-280-6933 nsales@ramcoi.com
Display
3.0000
1.5000
1.0000
0
0.5mm
2mm
-