When the orange MODE indicator next to the
is in the detection state. Judgment is output in the detection state accord-
ing to the upper and lower limit settings. With the GO judgment, a value is
displayed in green on the lower line. With the LO or HI judgment, a value is
displayed in orange on the upper line.
LO/GO/HI indicator
The range of the detected value can be checked on the LO/GO/HI indicator.
Press the
tings (but the settings cannot be changed). At this time, the MODE indicator
at the
Press the
on the upper line and the measured value on the lower line.
Press the
Ramco Innovations www.ramcoi.com
Detection Mode
Detected value displayed when the upper limit setting is "1.0000" and the
lower limit setting is "0.5000".
In the case of within range (GO)
MODE indicator
HI indicator (orange) : Lights up with measurements larger than the upper
GO indicator (green) : Lights up with measurements between the upper
LO indicator (orange) : Lights up with measurements smaller than the low-
*In the case of holding measurement and calculation measurement, the
measured value is displayed.
or
key in the detection state to check the following item set-
key is not lit.
key in the detection state to display the current detected value
key to return to the original state.
Detection state
Upper limit setting
Lower limit setting
Averaging frequency
Application mode
In the case of beyond range (LO or HI)
limit setting.
and lower limit values.
er limit value.
When the