Panasonic GP-X Series User Manual page 48

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

Cyclic Trigger Mode
In the cyclic trigger mode, the trigger is generated periodically and held in the
trigger interval.
The trigger is generated for each period.
The interval from the trigger point to the next trigger point is the sampling pe-
riod.
The analog output or judgment output is updated after the sampling period.
The TIMING indicator (green) lights up with a trigger.
In the cyclic trigger mode, no strobe output is issued.
The trigger delay time and sampling time settings are ignored.
Enter a period other than "0" for the cyclic trigger.
Example of bottom hold
Displayed value
0
Internal sampling
ON
Timing indicator
OFF
42
Ramco Innovations www.ramcoi.com
Trigger period
Sampling period 1
Start of holding mode
Output of result of
sampling period 1
Trigger period
Sampling period 2
Phone 800-280-6933 nsales@ramcoi.com
Measured value
Measurement
Displayed value
Output value
Output of result of
sampling period 2
Trigger period
Sampling period 3
Time