Manual Mode - Panasonic GP-X Series User Manual

High-speed high-accuracy eddy current digital displacement sensor
Hide thumbs Also See for GP-X Series:
Table of Contents

Advertisement

3.4.2 Manual Mode: "

There are the following variations in the detection function that are available
in the manual mode.
Indication
Reference
Setting example
Select peak hold.
<Detection state>
<Application mode>
<Manual mode>
54
Ramco Innovations www.ramcoi.com
Name
Normal
Peak hold
Bottom hold
Peak-to-peak hold
Sample hold
Average hold
For each holding measurement, refer to section "2.3.1 Holding Measure-
ment Function" on page 32.
Press
" (manual)
Description of action
The measurement result is displayed and
output whenever necessary.
The maximum value in the designated
interval is measured.
The minimum value in the designated
interval is measured.
The difference between the maximum and
minimum values in the designated interval
is measured.
The momentary value at the designated
timing is measured.
A simple mean of the measurement interval
is measured.
to select "APPLI".
Press
to select peak hold.
Phone 800-280-6933 nsales@ramcoi.com
Set
<Peak hold>

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp-x3sGp-x5sGp-x8sGp-x10mGp-x12mlGp-x22kl

Table of Contents