6) Press the

3.4.4 Rotation/Eccentricity Detection Mode: "

Use this mode to detect eccentricity in the rotation of a shaft. The minimum
reference trigger and the peak-to-peak distance is measured in the sampling
period to output judgment in comparison with the preset upper and lower
limit values.
After the rotation/eccentricity detection mode is selected, the following
measuring conditions are set.
The internal trigger level, trigger edge direction, trigger delay and sampling
time are ignored.
Comparison with previous mean is invalid.
To use the external trigger, internal trigger with a trigger level, or cyclic
trigger, select the manual mode and enter settings.
1) Mount the sensor head on equipment.
2) Adjust the sensor head and the position of the object to be detected.
Ramco Innovations www.ramcoi.com
key to return to the detection state.
For details of the upper/lower limit value entry method, refer to section "3.2
Reference
Upper and Lower Limit Value Settings" on page 48.
For the detection action, refer to the example of the internal trigger mode
with zero sampling time described on page 41.
Enter settings so that the internal trigger level and the sum of the internal
trigger level and trigger hysteresis become within 110% and within 120% of
the maximum detection distance, respectively.
POINT
Press the
Reference
the upper line) and measured value (on the lower line). For details, refer to
" Detection Mode" on page 27.
・The trigger condition is set with a trigger hysteresis.
Example of detection of eccentricity
For mounting of the sensor head, refer to section "1.6.2 Mounting the
Reference
Sensor Head" on page 17.
1. Select the material according to the object to be detected.
Refer to section "4.1 Selection of Object to Be Detected" on page 70 for
Reference
selection of the material.
If the object to be detected is iron, select "FE". The factory shipment setting of
GP-X series is stainless steel (SUS304).