3) Designate controllers 2 and 3 as slaves.
If the interference prevention function is used, the trigger delay, sampling
time, cyclic trigger interval and output delay settings vary according to the
measuring time ratio (duty) determined by the number of connected units.
Number of connected units and measurement time ratio
GP-X3S, GP-X5S, GP-X8S
GP-X10M, GP-X12ML
GP-X22KL
Setting items related to time:
For example, with a "1.0 sec." setting of the cyclic trigger in a system con-
necting three units, the actual period becomes 4.8 sec. To obtain a 1.0 sec.
period, enter "0.2083 sec."
(Example)
2 units of GP-X12ML and 6units of GP-X22KL (total 8 units) are used:
Ramco Innovations www.ramcoi.com
(Slave)
Timing chart of interference prevention action
Measurement
Controller 1
(Master)
Controller 2
(Slave)
Controller 3
(Slave2)
If the interference prevention input and output cables are not connected
correctly to the external terminal, detection is stopped and the correct ac-
Notice
tion is not obtained even if the interference prevention function is validated.
2 units
The measurement time ratio of GP-X12ML is 12.8 times each.
The measurement time ratio of GP-X22KL is 19.2 times each.
Press
to select "slave".
Set
t1
Oscillation stop (measurement value hold) interval
t2
t1
Oscillation stop (measurement value hold) interval
Measurement
t2
GP-X3S, GP-X5S, GP-X8S
GP-X10M, GP-X12ML
GP-X22KL
3 units
4 units
3.2
4.8
6.4
4.8
7.2
9.6
Phone 800-280-6933 nsales@ramcoi.com
Measurement
t2
t1
Measurement
t1
1.5ms
1.0ms
5 units
6 units
7 units
8.0
9.6
11.2
12.0
14.4
16.8
Measurement
t2
0.9ms
1.4ms
8 units
12.8
19.2
91