4.5.2 Two-Point Scaling

trarily.
Ramco Innovations www.ramcoi.com
Set P1 (0.5mm) at "0.0000" and P2 (2mm) at "3.0000".
Voltage
(V)
5.0000
0
2mm
・Enter the detected value on the upper line and the displayed value on the
lower line.
If the setting is incorrect, an error is displayed. Press the
cancel the error and repeat entry.
<Setting error>
・The detected value is beyond the detection distance range.
POINT
value of the second point.
value of the second point.
・The span (inclination) becomes 3.2 times the default inclination or more.
・To reverse the span (inclination), select SLOPE" of one-point scaling or
use the INV function.
Voltage
(V)
5.0000
3.0000
P2
P1
0
0.5mm
2mm
-1.0000