NEC Electra Elite IPK II System User Manual page 984

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Document Revision 4C
11-10-08
Service Code Setup (for System Administrator) – Setting the Destination for Automatic
Trunk Transfer
If the default service code (735) for setting the destination of the Automatic Tandem Trunking
feature is not acceptable, change the code as required.
13-04-01
Speed Dialing Number and Name – Speed Dialing Data
Enter the number and names for the bins used to hold the Automatic Tandem Trunking
destination.
(default: No Setting)
13-04-02
Speed Dialing Number and Name – Name
Assign a name to each System Speed Dial bin.
(default: No Setting)
13-04-03
Speed Dialing Number and Name – Transfer Mode
Assign the transfer mode for each System Speed Dial bin.
13-04-04
Speed Dialing Number and Name – Transfer Destination Number
(default: No Setting)
13-04-05
Speed Dialing Number and Name – Incoming Ring Pattern
(default: 0)
14-01-04
Basic Trunk Data Setup – Transmit Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-05
Basic Trunk Data Setup – Receive Gain Level for Conference and Transfer Calls
Select the CODEC gain type used by the trunk when it is part of an Unsupervised Conference.
14-01-13
Basic Trunk Data Setup – Trunk-to-Trunk Transfer
For each trunk, enter 1 to enable loop supervision.
20-06-01
Class of Service for Extensions
Assign a Class of Service (1~15) to an extension.
20-07-05
Class of Service Options (Administrator Level) – Set/Cancel Automatic Trunk-to-Trunk
Transfer
Enable (1)/Disable (0) an extension ability to use the Trunk-to-Trunk Forwarding service codes.
(default: 0)
20-07-11
Class of Service Options (Administrator Level) – Forced Trunk Disconnect (analog trunk
only)
Enter 1 to enable Forced Trunk Disconnect. This allows the extension to disconnect an
Unsupervised Conference in progress.
24-02-07
System Options for Transfer – Trunk-to-Trunk Transfer Release Warning Tone
This timer (0~64800 seconds) starts when a trunk begins talking with another trunk (for
example: Trunk-to-Trunk Transfer, outgoing from trunk, Tandem Trunking).
(default:1800)
24-02-10
System Options for Transfer – Disconnect Trunk-to-Trunk
This timer (0~64800 seconds) starts after the Trunk-to-Trunk warning tone is heard.
(default: 0)
2 - 960
Tandem Trunking (Unsupervised Conference)
Electra Elite IPK II

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents