Electra Elite IPK II
Enhancements
Version 1500 or higher license allows for the system to have Session Initiation Protocol (SIP) Trunks/Stations.
Version 1600 or higher supports the 30-day promo license.
Description
Licenses are used to activate certain features and applications for the Electra Elite IPK II. The IPK II
provides the following licenses:
CPU Licenses
The IPK II CPU can be licensed for the following features:
InACD – This license allows the system to run the In ACD feature.
SMDR – This license allows the system to print SMDR reports.
Remote Software Upgrade – This license allows the system to be upgraded remotely.
MEGACO Stations – 16 MEGACO Station licenses are provided with every PVA card with MG16
or MGCCoIP applications installed when purchased, but more licenses can be purchased in
increments of one, four, or eight with a maximum of 256.
SIP – This license allows the system to have SIP Trunks/Stations. The licenses can be purchased
in increments of one, four, or eight with a maximum of 256. (Version 1500 or higher required.)
Hotel/Motel – This license allows the system to run the Hotel/Motel feature.
CTI – This license allows the system to have a third party CTI Server connected.
CPUII Feature Version License is required for the system to be upgraded to system software 2.0 or
higher.
Temporary 10-Day License
The Temporary 10-Day license turns on ACD, CTI, Remote Software Upgrade, Hotel/Motel, 256
MEGACO stations, and SMDR license for up to 10 days.