Electra Elite IPK II
15-07-01
Programmable Function Keys
KYxx = Key Number 01~32
KY01 =
KY01 =
15-08-01
Incoming Virtual Extension Ring Tone Setup
ICM Tone Pattern:
0 = Pattern 1 (default)
1 = Pattern 2
2 = Pattern 3
3 = Pattern 4
15-09-01
Virtual Extension Ring Assignment
Mode1.
0 = No (default)
1 = Yes
15-10-01
Incoming Virtual Extension Ring Tone Order Setup
Order 1 Patrn0 = Pattern 1 (default)
Order 2 Patrn1 = Pattern 2 (default
Order 3 Patrn2 = Pattern 3 (default)
Order 4 Patrn3 = Pattern 4 (default)
15-11-01
Virtual Extension Delayed Ring Assignment
KY01 Mode1:
1 = Yes
0 = No
(default: 0)
15-18-01
Virtual Extension Key Enhanced Options – Virtual Extension Key Operation Mode
0 = Release
1 = Land On The Key
(default: 0)
20-04-03
System Options for Virtual Extensions – CAR/SIE/Virtual Extension Delay Interval
Delay = 10 sec (default)
20-06-01
Class of Service for Extensions
Mode1 Class No. = 1 (default)
20-07-10
Class of Service Options (Administrator Level) – Programmable Function Key
Programming (Appearance Level)
1 = On (default)
0 = Off
20-10-08
Class of Service Options (Answer Service) – Virtual Extension Off-Hook Answer
0 = Off
1 = On (default)
20-13-27
Class of Service Options (Supplementary Service) – Busy on Seizing Virtual Extension
1 = On (default)
0 = Off
Secondary Incoming Extension
03 (Virtual Extension,
08 (CAP Key)
01 by default)