NEC Electra Elite IPK II System User Manual page 404

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Document Revision 4C
Each channel in the PGD(2)-U10 ADP has a jumper which must be set for Door Box
operation. Refer to the Electra Elite IPK II System Hardware Manual for additional details.
The PGD(2)-U10 ADP can be connected only to an ESIB(8)-U20 ETU. if the PGD(2)-U10
ADP is connected to an ESIE(8)-U20 ETU, the PGD(2)-U10 ADP is not recognized.
When a ESIB(8)-U20 ETU has an ESIE(8)-U20 ETU installed [ESIB/E(16)], the
PGD(2)-U10 ADP has both channels available for Paging, MOH, External Ringers and
Door Box according to strapping on ports 1~8. The corresponding port on the ESIE(8)-U20
ETU does not support a station or other hardware (it is used by the PGD(2)-U10 ADP for
channel 2).
When a ESIB(8)-U20 ETU is installed without an ESIE(8)-U20 ETU installed, a
PGD(2)-U10 ADP installed on ports 1~8 is recognized, but only channel 1 on the
PGD(2)-U10 ADP is supported. Channel 2 is not available.
ESIB(8)-U10 ETUs and ESIE(8)-U10 ETUs do not support the PGD(2)-U10 ADP.
A Single Line Telephone (SLT), connected to an APR does not ring when the Door Phone
rings the multiline telephone.
term
cordless telephones are not supported with the Door Box feature.
D
Door Boxes do not ring Logged In ACD Agents.
Default Setting
Disabled
System Availability
Terminals
All Stations
Required Component(s)
PGD(2)-U10 ADP
Programming
10-03-01
ETU Setup (For ESI PKG) – Terminal Type (B1)
10-03-06
ETU Setup (For ESI PKG) – Terminal Type (B2)
For ESI package support, set the terminal type to 8 [PGD (for Door Box)]. First set 10-03-01 to
0 with no device plugged into that port, then plug the device in and the system should recognize
it as a door box, and set PRG 10-03-06.