NEC Electra Elite IPK II System User Manual page 61

Hide thumbs Also See for Electra Elite IPK II System:
Table of Contents

Advertisement

Electra Elite IPK II
Required Component(s)
CTA/CTU and available USB port
- OR -
Available RS-232 Serial Communications Port
Related Features
None
Programming
15-02-19
Multiline Telephone Basic Data Setup – CTA Data Communications Setup
This Program must be set to Non-Procedural Mode (1) when using CTA/CTU adapters for
printouts.
0 = CTI Mode
1 = Non-Procedural Mode (Non-SCS)
15-02-20
Multiline Telephone Basic Data Setup – Baud Rate for CTA Port
0 = 4800bps
1 = 9600bps
2 = 19200bps (default)
90-10-01
System Alarm Setup – Alarm Type
0 = Not Set (default)
1 = Major Alarm
2 = Minor Alarm
90-10-02
System Alarm Setup – Report
0 = No Report (no autodial) (default)
1 = Report (autodial)
90-11-01
System Alarm Report – System Alarm Display Telephone
Assign the display multiline extension number that should receive system alarms.
Extension Number (up to eight digits).
No default is assigned
90-12-05
System Alarm Output – Clear All Alarm Reports
Clear all alarms.
All Clear?
0 = No
1 = Yes
Alarm Reports
Document Revision 4C
2 - 37