Document Revision 4C
Trunk Continue/Disconnect Codes
14-01-25
Basic Trunk Data Setup – Continued/Discontinued Trunk-to-Trunk Conversation
When Program 24-02-10 is set to disconnect a trunk after the defined time, determine whether
or not a user should be able to use the continue/disconnect code.
0 = Disable
1 = Enable
20-28-01
Trunk to Trunk Conversation – Conversation Continue Code
When Program 14-01-25 is enabled, determine the 1-digit code the user should dial (0~9,
to extend the conversation for the time defined in PRG 20-28-03. If the Continue and Disconnect
codes are programmed the same (e.g., #), the system follows the Continue operation. Using the
Continue code before the warning tone is heard has no action.
20-28-02
Trunk to Trunk Conversation – Conversation Disconnect Code
When Program 14-01-25 is enabled, determine the 1-digit code the user should dial (0~9,
to immediately disconnect their call. Using the Disconnect code before the warning tone is heard
disconnects the call.
20-28-03
Trunk to Trunk Conversation – Conversation Continue Time
When Program 14-01-25 is enabled, determine the time a call is extended (0~64800 seconds)
when the user dials the Continue code (defined in PRG 20-28-01).
24-02-07
System Options for Transfer – Trunk-to-Trunk Transfer Release Warning Tone
This timer starts when a trunk begins talking with another trunk (for example: Trunk-to-Trunk
Transfer/Tandem Trunking). When this time expires, a warning tone is heard. If Program
24-02-10 is set, the conversation disconnects after that time expires. This timer is set again
when the external digit time expires. One of the trunks used must be an analog trunk (or leased
line). Entries: (0~64800 seconds).
This applies to manually transferred Tandem Trunk and DISA calls.
24-02-10
System Options for Transfer – Disconnect Trunk-to-Trunk
Determine the time (0~64800 seconds) a conversation continues after the time in Program
24-02-07 expires. If this option is set to 0, the conversation is disconnected immediately. This
program has no affect if Program 24-02-07 is set to 0. One of the trunks used must be an analog
trunk (or leased line).
This applies to manually transferred Tandem Trunk and DISA calls.
25-07-07
System Timers for VRS/DISA – Long Conversation Warning Tone Time
Determine the time a DISA caller can talk before the Long Conversation tone is heard (0~64800
seconds). If Program 25-07-08 is set to 0, the call is disconnected after the time expires. This
timer is set again when the external digit time expires. Default is 3600.
This applies to automatically transferred Tandem Trunk and DISA calls.
25-07-08
System Timers for VRS/DISA – Long Conversation Disconnect Time
Determine the time the system waits (0~64800 seconds) before disconnecting a DISA call after
the Long Conversation tone is heard. This program has no affect if Program 25-07-07 is set to 0.
Default is 10.
This applies to automatically transferred Tandem Trunk and DISA calls.