NEC Univerge SV8100 Features And Specifications Manual page 964

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Program
Program Name
Number
80-04-01
Call Progress Tone Detector Setup
– Detection Level
80-04-04
Call Progress Tone Detector Setup
– No tone time
82-11-01
LCA Initial Setup – Bounce
Protect Time
82-11-02
LCA Initial Setup – HookFlash
Start Time
82-11-03
LCA Initial Setup – HookFlash End
Time
Operation
Refer to the individual features listed in the Related Features section above in this feature.
2 - 940
Description/Comments
If required, modify the criteria for
dial tone detection and call progress
tone detection for the DTMF tones
received at a single line telephone.
Use this option to set No Tone Time. 0~255 (30+30-7680ms)
Specify a time for detection of a
valid 0ff-Hook indication that is long
enough to prevent an unintentional
bounce of the receiver from being
detected as a new Off-Hook
indication from a Single Line
Telephone.
Specify the minimum hookflash time
from a Single Line Telephone or
analog Voice Mail system before it is
detected as the beginning of a valid
hookflash.
Define various timers for the SLI
ETUs. The entries you make in this
program affect all SLI ETUs
installed.
UNIVERGE SV8100
Assigned Data
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
default:
Type 1 (DT) – 0
(-25dBm)
Type 2 (BT) – 0
(-25dBm)
Type 3 (RBT) – 0
(-25dBm)
Type 4, Type 5 – 0
default:
Type 1 (DT) – 132 (3990ms)
Type 2 (BT) – 132 (3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
0 = No Setting
1~15 = 100ms~1.5sec
(default = 3)
0 = 40ms
1~15 = 90ms~790ms
(default = 5 [290ms])
0 = HST+0ms 1~15 =
HST+100ms~HST+1500ms
(HST=Hookflash Start Time)
(default = 7)
Single Line Telephones
Level
1
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents