NEC Univerge SV8100 Features And Specifications Manual page 692

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Program
Program Name
Number
20-13-23
Class of Service Options
(Supplementary Service) –
Display the Reason for Transfer
20-19-02
Caller ID Wait Timer
20-19-03
Caller IDEdit Mode
20-19-04
System Options for Caller ID –
Wait Facility IE Timer
20-25-14
ISDN Options – No response
Release Send
Operation
None
2 - 668
Description/Comments
Select whether an extension should
display the reason a call is being
transferred to their extension (Call
Forward Busy, Call Forward No
Answer, DND).
This is the time an ISDN trunks
uses to determine how long the
system waits for the Caller ID name
from the Telco.
Operation mode setting for when
second T303 timer expires.
UNIVERGE SV8100
Assigned Data
1
0 = Off
1 = On
(default = 0 for
COS 1~15)
2 seconds
1 = On
0~64800 seconds
(default = 10)
0 = Off
1 = On
(default = 0)
ISDN Compatibility
Level
2
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents