Issue 1.0
Program
Program Name
Number
80-03-04
DTMF Tone Receiver Setup –
Max. Detect Level
80-03-05
DTMF Tone Receiver Setup –
Forward Twist Level
2 - 758
Description/Comments
Use this option to define the
maximum detection level for
DTMF Tone Receiver.
Use this option to define the
forward twist level for DTMF Tone
Receiver.
UNIVERGE SV8100
Assigned Data
0~15
detect level 0: 0dBm(0)
to –15dBm(15)
detect level 1:
–5dBm(0) to –
20dBm(15)
detect level 2:
–10dBm(0) to –
25dBm(15)
detect level 3:
–15dBm(0) to –
30dBm(15)
detect level 4:
–20dBm(0) to –
35dBm(15)
detect level 5:
–25dBm(0) to –
40dBm(15)
detect level 6:
–30dBm(0) to –
45dBm(15)
detect level 7: -35dBm(0)
to -50dBm(15)
detect level 8: -40dBm(0)
to -55dBm(15)
detect level 9: -45dBm(0)
to -60dBm(15)
detect level 10: -
50dBm(0) to -
65dBm(15)
detect level 11: -
55dBm(0) to -
70dBm(15)
detect level 12: -
60dBm(0) to -
75dBm(15)
detect level 13: -
65dBm(0) to -
80dBm(15)
detect level 14: -
70dBm(0) to -
85dBm(15)
detect level 15: -
75dBm(0) to -
90dBm(15)
default:
Type 1~5 = 0
0~9
(1dB ~ 10dB)
default:
All Receivers = 9
Multiple Trunk Types
Level
1
2
3