ABB TPU2000 Technical Manual page 71

Modbus/modbus plus/ modbus tcp/ip automation
Table of Contents

Advertisement

Register
Address
3
00116
Reserved
3
00117
Reserved
3
00118
Reserved
3
00119
Reserved
3
00120
Reserved
3
00121
Reserved
3
00122
Reserved
3
00123
Reserved
3
00124
Reserved
3
00125
Reserved
3
00126
Reserved
3
00127
Reserved
3
00128
Reserved
3
00129
51P-3
3
00130
50P-3
3
00131
150P-3
3
00132
51N-3
3
00133
50N-3
3
00134
150N-3
3
00135
46-3
3
00136
51G
3
00137
50G
3
00138
150G
3
00139
51P-3D
3
00140
50P-3D
3
00141
150P-3D
3
00142
51N-3D
3
00143
50N-3D
3
00144
150N-3D
3
00145
46-3D
3
00146
51GD
3
00147
50GD
3
00148
150GD
(L) 3
00149
51P-3*
(L) 3
00150
50P-3*
(L) 3
00151
150P-3*
(L) 3
00152
51N-3*
(L) 3
00153
50N-3*
(L) 3
00154
150N-3*
(L) 3
00155
46-3*
(L) 3
00156
51G*
(L) 3
00157
50G*
(L) 3
00158
150G*
3
00159
TFKA-3
3
00160
HLDA-3
3
00161
LLDA-3
TPU2000/2000R Modbus/Modbus Plus Automation Guide
Item
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Winding 3 Phase Time Overcurrent Alarm Energized
st
1
Winding 3 Phase Instantaneous Overcurrent Trip Alarm Energized
nd
2
Winding 3 Phase Instantaneous Overcurrent Trip Alarm Energized
Winding 3 Neutral Time Overcurrent Alarm Energized
st
1
Winding 3 Neutral Instantaneous Overcurrent Trip Alarm Energized
nd
2
Winding 3 Neutral Instantaneous Overcurrent Trip Alarm Energized
Winding 1 Negative Sequence Time Overcurrent Trip Alarm Energized
Ground Time Overcurrent Control Energized
st
1
Ground Time Instantaneous Overcurrent Control Energized
nd
2
Ground Time Instantaneous Overcurrent Control Energized
Winding 3 Phase Time Overcurrent Function Disabled Alarm Energized
st
1
Winding 3 Phase Instantaneous Overcurrent Function Disabled Alarm
Energized
nd
2
Winding 3 Phase Instantaneous Overcurrent Disable Alarm Energized
Winding 3 Phase Time Overcurrent Function Disabled Alarm Energized
st
1
Winding 3 Neutral Instantaneous Overcurrent Function Disabled
Alarm Energized
nd
2
Winding 3 Neutral Instantaneous Overcurrent Disable Alarm Energized
Winding 3 Negative Sequence Tiem Overcurrent Function Disabled Alarm
Energized
Ground Time Overcurrent Trip Alarm
st
1
Winding 3 Ground Instantaneous Overcurrent Disable Alarm Energized
nd
2
Winding 3 Ground Instantaneous Overcurrent Disable Alarm Energized
Winding 3 Phase Time Overcurrent Alarm Energized Seal In
st
1
Winding 3 Phase Instantaneous Overcurrent Trip Alarm Energized Seal
In
nd
2
Winding 3 Phase Instantaneous Overcurrent Trip Alarm Energized
Seal In
Winding 3 Neutral Time Overcurrent Alarm Energized Seal In
st
1
Winding 3 Neutral Instantaneous Overcurrent Trip Alarm Energized
Seal In
nd
2
Winding 3 Neutral Instantaneous Overcurrent Trip Alarm Energized
Seal In
Winding 1 Negative Sequence Time Overcurrent Trip Alarm Energized
Seal In
Ground Time Overcurrent Control Energized Seal In
st
1
Ground Time Instantaneous Overcurrent Control Energized Seal In
nd
2
Ground Time Instantaneous Overcurrent Control Energized Seal In
Through Fault KiloAmps Symmetrical Winding 3
Winding 3 High Level Detector Alarm Energized
Winding 3 Low Level Detector Alarm Energized