05.05
P046 (0)
.01
B
.02
B
.03
B
.04
B
U181 (0)
KK
The selected setting can be entered in the empty field (fields). The value in brackets next to the
parameter number is the factory setting of the selection parameter.
The following rules apply to the selection of double-word connectors (SW 1.9 and later):
U181 (0)
KK9498
K0401
KK9498
KK9498
KK9498
U751 (0)
KK9498
KK9499
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Selection of binectors ("indexed" parameter with 4 indices)
Parameter number = P046, factory setting = 0 (i. e. fixed value 0, this factory setting
applies to all the indices of P046)
Selection of a double-word connector (SW 1.9 and later)
Parameter number = U181, factory setting = 0 (i.e. fixed value 0%)
Double-word connector to double-word connector selection:
9498
KK
The double word for subsequent processing comprises:
LOW word = LOW word of double-word connector (KK9498)
HIGH word = HIGH word of double-word connector (KK9498)
U181
Connector to double-word connector selection:
401
KK
The double word for subsequent processing comprises:
LOW word = 0
HIGH word = selected connector (K0401)
P044
Double-word connector to connector selection:
9498
K
HIGH word of the double-word connector (KK9498) is connected to
another block,
the LOW word of the double-word connector (KK9498) is not used
There are exceptions in the selection of transmission data for the serial
U751 (0)
.01
9498
K
L
interfaces and in the transmission of optional expansion modules
.02
9498
H
K
(technology and communications modules, SIMOLINK module):
If the same double-word connector is entered in two contiguous indices of
the selection parameter, the entire value (the LOW and HIGH word) will be
used.
If different double-word connectors are entered in two contiguous indices
.01
K
9498
H
of the selection parameter, in both cases only the HIGH word of the two
.02
K
9499
H
double-word connectors will be used.
Function descriptions
9-3