Siemens 6RA7086-6KS22 Operating Instructions Manual page 515

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
11.23 Position sensing with pulse encoder
See parameters P140 to P148 for pulse encoder definition and monitoring
P450
Resetting of position counter
*
0
Reset position counter OFF
FDS
1
Reset position counter with zero marker
(G145)
2
Reset position counter with zero marker when LOW signal is
applied to terminal 39
3
Reset position counter when LOW signal is applied to terminal
39
Note: Counter resetting with P450 = 2 and 3 is executed in the hardware
and is not affected by how the binectors controlled by terminal 39 are
interconnected
P451
Position counter hysteresis
*
0
Hysteresis for rotational direction reversal OFF
FDS
1
Hysteresis for rotational direction reversal ON (the first pulse
encoder input pulse after a change in rotational direction is not
(G145)
counted)
P452
Source for "Reset position counter" command
*
Selection of binector to control resetting of the position counter.
BDS
0 = binector B0000
1 = binector B0001
(G145)
etc.
P453
Source for "Enable zero marker counter" command
*
Selection of binector to control enabling of the zero marker counter
BDS
0 = binector B0000
1 = binector B0001
(G145)
etc.
11.24 Connector selector switches
(see also Section 8, Function Diagram Sheet G124)
P455
Source for inputs of connector selector switch 1
*
Selection of connectors for the input signals for connector selector switch 1.
(G124)
0 = connector K0000
1 = connector K0001
etc.
P456
Source for control of connector selector switch 1
*
Selection of binectors to control connector selector switch 1.
(G124)
0 = binector B0000
1 = binector B0001
etc.
P457
Source for inputs of connector selector switch 2
*
Selection of connectors for the input signals for connector selector switch 2.
(G124)
0 = connector K0000
1 = connector K0001
etc.
P458
Source for control of connector selector switch 2
*
Selection of binectors to control connector selector switch 2.
(G124)
0 = binector B0000
1 = binector B0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
0 to 3
1
0 to 1
1
All binector numbers
[SW 1.9 and later]
1
All binector numbers
[SW 1.9 and later]
1
All connector
[SW 1.9 and later]
numbers
1
[SW 1.9 and later]
All binector numbers
1
[SW 1.9 and later]
All connector
numbers
1
All binector numbers
[SW 1.9 and later]
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=1
P051 = 40
Type: O2
Offline
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
off-line
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
off-line