Siemens 6RA7086-6KS22 Operating Instructions Manual page 594

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
11.68 Logic functions
Only active with optional technology software S00
Decoders/demultiplexers, binary to 1 of 8
U318
Source for input signals for decoder/demultiplexer 1
(2318)
i001
Source for input signal, bit 0
*
i002
Source for input signal, bit 1
S00
i003
Source for input signal, bit 2
(B200)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U319
Source for input signals for decoder/demultiplexer 2
(2319)
i001
Source for input signal, bit 0
*
i002
Source for input signal, bit 1
S00
i003
Source for input signal, bit 2
(B200)
Settings:
0 = binector B0000
1 = binector B0001
etc.
AND elements with 3 inputs each
The input signals selected via the 3 indices of the parameter are ANDed and the result of the logic operation applied to the specified
binector.
Source for input signals, AND element 1 (output = B9350)
U320
(2320)
i001
Source for input 1
*
i002
Source for input 2
S00
i003
Source for input 3
(B205)
Settings:
0 = binector B0000
1 = binector B0001
etc.
Source for input signals, AND element 2 (output = B9351)
U321
(2321)
As for U320
*
S00
(B205)
Source for input signals, AND element 3 (output = B9352)
U322
(2322)
As for U320
*
S00
(B205)
Source for input signals, AND element 4 (output = B9353)
U323
(2323)
As for U320
*
S00
(B205)
Source for input signals, AND element 5 (output = B9354)
U324
(2324)
As for U320
*
S00
(B205)
Source for input signals, AND element 6 (output = B9355)
U325
(2325)
As for U320
*
S00
(B205)
Source for input signals, AND element 7 (output = B9356)
U326
(2326)
As for U320
*
S00
(B205)
11-130
Value range
[Unit]
Steps
All binector numbers
FB 118
1
All binector numbers
FB 119
1
All binector numbers
FB 120
1
All binector numbers
FB 121
1
All binector numbers
FB 122
1
All binector numbers
FB 123
1
All binector numbers
FB 124
1
All binector numbers
FB 125
1
All binector numbers
FB 126
1
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents