Parameter list
PNU
Description
Connector changeover switches 6 and 11
U250
Source for input quantities
(2250)
Output 6 = Connector K9215
*
i001:
1st input signal
S00
i002:
2nd input signal
(B150)
Output 11 = Connector K9265
i003:
1st input signal
i004:
2nd input signal
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
U251
Source for control signal
(2251)
i001:
Switchover for output 6
*
i002:
Switchover for output 11
S00
(B150)
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
Connector changeover switches 7 and 12
U252
Source for input quantities
(2252)
Output 7 = Connector K9216
*
i001:
1st input signal
S00
i002:
2nd input signal
(B150)
Output 12 = Connector K9266
i003:
1st input signal
i004:
2nd input signal
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
U253
Source for control signal
(2253)
i001:
Switchover for output 7
*
i002:
Switchover for output 12
S00
(B150)
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
Connector changeover switches 8 and 13
U254
Source for input quantities
(2254)
Output 8 = Connector K9217
*
i001:
1st input signal
S00
i002:
2nd input signal
(B150)
Output 13 = Connector K9267
i003:
1st input signal
i004:
2nd input signal
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
U255
Source for control signal
(2255)
i001:
Switchover for output 8
*
i002:
Switchover for output 13
S00
(B150)
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
11-120
Value range
[Unit]
Steps
All connector
FB 95 and FB 196
numbers
1
[SW2.0 and later]
All binector numbers
FB 95 and FB 196
1
[SW2.0 and later]
All connector
FB 96 and FB 197
numbers
1
[SW2.0 and later]
All binector numbers
FB 96 and FB 197
1
[SW2.0 and later]
All connector
FB 97 and FB 198
numbers
1
[SW2.0 and later]
All binector numbers
FB 97 and FB 198
1
[SW2.0 and later]
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
SIEMENS AG
6RX1700-0AD76
Operating Instructions