Parameter list
PNU
Description
r810
Receive data on G-SST1
Display of data received via USS interface 1
(G170)
i001:
Display process data word 1
...
i016
Display process data word 16
i017:
Display parameter data word 1
...
i020:
Display parameter data word 4
r811
Transmit data on G-SST1
Display of the data to be transmitted via USS interface 1
(G170)
i001:
Display process data word 1
...
i016
Display process data word 16
i017:
Display parameter data word 1
...
i020:
Display parameter data word 4
r812
Receive data on G-SST2
When USS protocol (P790=2) is selected:
(G171)
Display of data received via USS interface 2
(G173)
i001:
Display process data word 1
...
i016
Display process data word 16
i017:
Display parameter data word 1
...
i020:
Display parameter data word 4
When peer-to-peer (P790=5) is selected:
Display of data received via peer-to-peer interface 2
i001:
Receive data word 1
...
i005
Receive data word 5
i006:
Not used
...
i020
Not used
When communication with the SIMOREG CCP is selected (P790 = 6):
Data received from the SIMOREG CCP via interface 2 is displayed
i001:
Last received 1-byte message
i002:
Last received header of a multibyte message
...
i018
Free-running counter for the number of received 1-byte
messages
i019
Free-running counter for the number of received headers of a
multibyte message
i020
Free-running counter for the number of received sequence bytes
of a multibyte message
11-90
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
Ind: 20
Type: L2
Ind: 20
Type: L2
Ind: 20
Type: L2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P052 = 3
P052 = 3
6RX1700-0AD76