Siemens 6RA7086-6KS22 Operating Instructions Manual page 598

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
Source for input signals, OR element 20 (output = B9399)
U369
(2369)
As for U350
*
S00
(B206)
EXCLUSIVE OR elements with 2 inputs each
The input signals selected via the 2 indices of the parameter are combined in an EXCLUSIVE OR (XOR) operation and the result applied
to the specified binector..
Source for input signals, XOR element 1 (output = B9195)
U370
(2370)
i001
Source for input 1
*
i002
Source for input 2
S00
(B206)
Settings:
0 = binector B0000
1 = binector B0001
etc.
Source for input signals, XOR element 2 (output = B9196)
U371
(2371)
As for U370
*
S00
(B206)
Source for input signals, XOR element 3 (output = B9197)
U372
(2372)
As for U370
*
S00
(B206)
Source for input signals, XOR element 4 (output = B9198)
U373
(2373)
As for U370
*
S00
(B206)
Inverters
The input signal is inverted and the result applied to the specified binector.
Source for input signal, inverter 1 (output = B9450)
U380
(2380)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B207)
Source for input signal, inverter 2 (output = B9451)
U381
(2381)
As for U380
*
S00
(B207)
Source for input signal, inverter 3 (output = B9452)
U382
(2382)
As for U380
*
S00
(B207)
Source for input signal, inverter 4 (output = B9453)
U383
(2383)
As for U380
*
S00
(B207)
Source for input signal, inverter 5 (output = B9454)
U384
(2384)
As for U380
*
S00
(B207)
Source for input signal, inverter 6 (output = B9455)
U385
(2385)
As for U380
*
S00
(B207)
Source for input signal, inverter 7 (output = B9456)
U386
(2386)
As for U380
*
S00
(B207)
11-134
Value range
[Unit]
Steps
All binector numbers
FB 169
1
All binector numbers
FB 170
1
All binector numbers
FB 171
1
All binector numbers
FB 172
1
All binector numbers
FB 173
1
All binector numbers
FB 180
1
All binector numbers
FB 181
1
All binector numbers
FB 182
1
All binector numbers
FB 183
1
All binector numbers
FB 184
1
All binector numbers
FB 185
1
All binector numbers
FB 186
1
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents