Siemens 6RA7086-6KS22 Operating Instructions Manual page 521

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
Source for input signal of the friction compensation [SW 2.0 and later]
P519
*
Selection of the input signals that are added and led to the input of the
friction compensation.
(G153)
i001
Input signal, with sign
i002
Input signal with absolute value generator
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
P520
Friction at 0% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P521
Friction at 10% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P522
Friction at 20% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P523
Friction at 30% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P524
Friction at 40% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P525
Friction at 50% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P526
Friction at 60% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P527
Friction at 70% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P528
Friction at 80% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P529
Friction at 90% speed
FDS
Setting as % of converter rated DC current or rated torque
(G153)
P530
Friction at 100% speed and higher
FDS
Setting as % of converter rated DC current or rated torque
(G153)
11.31 Compensation of moment of inertia (dv/dt injection)
(see also Section 8, Sheet G153)
P540
Acceleration time
The acceleration time is the time that would be needed to accelerate the
FDS
drive from 0% to 100% of maximum speed (with no friction) at 100%
converter rated DC current (armature) and 100% rated motor field current
(G153)
(i.e. 100% flux). It is a measure of the moment of inertia on the motor shaft.
This parameter is set automatically during the optimization run for friction
and moment of inertia compensation (P051=28).
P541
P gain of acceleration
FDS
Proportional gain for "SAD-dependent acceleration" function (see also
(G153)
parameter P543)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 2
numbers
FS=
1
i001: 179
i002: 0
Type: L2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.00 to 650.00
Ind: 4
[s]
FS=0.00
0.01s
Type: O2
0.00 to 650.00
Ind: 4
0.01
FS=0.00
Type: O2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
11-57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents