Siemens 6RA7086-6KS22 Operating Instructions Manual page 634

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
U785
Filtering time for analog outputs on EB2
(2785)
i001: AO of the first EB2
i002: AO of the second EB2
(Z118)
(Z119)
U786
Normalization of analog outputs on EB2
(2786)
U
786
=
y
V [
]
x
100
%
x = normalization input (corresponds to filtering output)
(Z118)
y = normalization output (corresponds to output voltage at analog output
(Z119)
with an offset of 0)
i001: AO of the first EB2
i002: AO of the second EB2
U787
Offset for analog output on EB2
(2787)
i001: AO of the first EB2
i002: AO of the second EB2
(Z118)
(Z119)
n788
Display of analog outputs on EB2
(2788)
i001: AO of the first EB2
i002: AO of the second EB2
(Z118)
(Z119)
11.88 Configuring the SBP pulse encoder board
U790
Configuration of input level of A/B and CRTL tracks
(2790)
0:
HTL unipolar
*
1:
TTL unipolar
(Z120)
2:
HTL differential input
3:
TTL/RS422 differential input
U791
Configuration of encoder supply voltage
(2791)
The supply is subject to a current limit of 250mA
*
Caution: Setting the parameter incorrectly can damage the encoder (i.e. 15
V voltage for an encoder which requires a 5 V supply).
(Z120)
0:
5V voltage supply
1:
15V voltage supply
U792
Number of pulses per revolution
(2792)
Number of lines on one track around circumference of disk
*
(Z120)
U793
Encoder type
(2793)
0:
Encoder with A/B track (two tracks displaced by 90 degrees)
*
1:
Encoder with separate forward and reverse tracks
(Z120)
U794
Reference speed
(2794)
When actual speed = reference speed a value of 100% is output in the
(Z120)
appropriate diagnostic parameter (n795) and connector
n795
Display of actual speed in % of reference speed
(2795)
(Z120)
U796
Resetting the position counter
(2796)
Setting the type of resetting for position acquisition
*
S00
0 = free-running (no reset)
(Z120)
1 = see function diagram Z120
2 = see function diagram Z120
11-170
Value range
[Unit]
Steps
[SW 1.5 and later]
0 to 10000
[ms]
1ms
-200.00 to 199.99
[SW 1.5 and later]
[V]
0.01V
-10.00 to 10.00
[SW 1.5 and later]
[V]
0.01V
[SW 1.5 and later]
-200.00 to 199.99
[%]
0.01%
0 to 3
[SW 1.5 and later]
1
[SW 1.5 and later]
0 to 1
1
100 to 20000
[SW 1.5 and later]
1
[SW 1.5 and later]
0 to 1
1
50.0 to 6500.0
[SW 1.5 and later]
[rev/min]
0.1
[SW 1.5 and later] -200.00 to 199.99
[%]
[SW 2.0 and later]
0 to 2
1
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 2
P052 = 3
FS=10.00
P051 = 40
Type: I2
Online
Ind: 2
P052 = 3
FS=0.00
P051 = 40
Type: I2
Online
Ind: 2
P052 = 3
Type: I2
Ind: None
P052 = 3
FS=1
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=1024
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=500.0
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
Type: I2
Ind: none
P052 = 2
FS=0
P051 = 40
Type: O2
online
SIEMENS AG
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents