Parameter list
PNU
Description
11.14 Closed-loop EMF control
P272
Operating mode of closed-loop EMF control
*
0
Fault message F043 ("EMF too high for braking operation") is
(G165)
active: If the EMF is too high when a torque direction change is
requested (i.e. if the calculated firing angle (K0101) for the
armature current in the new torque direction is > 165 degrees),
both torque directions are disabled. If, at the same time, the
absolute value of the armature current required in the new
torque direction is > 0.5% of rated converter DC current
(P072.002), fault message F043 is activated (see Section 10 for
possible fault causes).
1
Alarm A043 and automatic field reduction if EMF is too high in
braking operation.
If the EMF is too high in braking operation (i.e. if the following
applies to the armature firing angle α before limitation (K0101):
α > ( α W – 5 degrees)), alarm A043 is activated ( α W is the
inverter stability limit according to P151 or 165 degrees with a
discontinuous armature current).
The field is reduced with activation of A043. This field reduction
is achieved by regulating the armature firing angle to ( α W – 5
degrees) by means of a P controller, whose output reduces the
EMF controller setpoint. "Field weakening operation by internal
closed-loop EMF control" (P081=1) must therefore be
parameterized so that the field reduction can take effect.
When a torque direction change is requested, both torque
directions remain disabled until the field, and thus the EMF,
have been reduced accordingly (i.e. until the calculated firing
angle (K0101) for the armature current required in the new
torque direction is <165 degrees).
P273
Control word for EMF controller precontrol
*
0
EMF controller precontrol disabled, precontrol output = rated
FDS
motor field current (P102)
(G165)
1
EMF controller precontrol is active
P274
Set EMF controller I component to zero
*
0
Set controller I component to zero (i.e. to obtain pure P
FDS
controller)
(G165)
1
Controller I component is active
P275
EMF controller P gain
*
This parameter is automatically set during the field weakening optimization
FDS
run (P051=27).
(G165)
P276
EMF controller reset time
*
This parameter is automatically set during the field weakening optimization
FDS
run (P051=27).
(G165)
P277
EMF controller droop
*
FDS
(G165)
Filter time for setpoint for EMF controller precontrol [SW 1.9 and later]
P280
Filtering of the EMF setpoint at the input of the EMF controller precontrol.
FDS
The purpose of this filter is to decouple the EMF controller precontrol from
(G165)
the EMF controller.
P281
Filter time for setpoint for EMF controller
Filtering of the EMF setpoint at the input of the EMF controller.
FDS
The purpose of this filter is to decouple the EMF controller precontrol from
(G165)
the EMF controller.
P282
Filter time for actual value for EMF controller
FDS
Filtering of actual EMF value at the input of the EMF controller.
(G165)
11-40
Value range
[Unit]
Steps
0 to 1
1
0 to 1
1
0 to 1
1
0.10 to 100.00
0.01
0.010 to 10.000
[s]
0.001s
0.0 to 10.0
[%]
0.1%
0 to 10000
[ms]
1ms
0 to 10000
[SW 1.9 and later]
[ms]
1ms
[SW 1.9 and later]
0 to 10000
[ms]
1ms
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 4
P052 = 3
FS=1
P051 = 40
Type: O2
Offline
Ind: 4
P052 = 3
FS=1
P051 = 40
Type: O2
Offline
Ind: 4
P052 = 3
FS=0.60
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.200
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0.0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
on-line
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
on-line
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
on-line