Siemens 6RA7086-6KS22 Operating Instructions Manual page 538

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
P694
Source for selection of enabling command for "Torque limit
*
switchover"
BDS
Selection of binector which is to control enabling of the "Torque limit
switchover" function (1=enable, see also Sheet G160 in Section 8 and P180
(G160)
to P183)
0 = binector B0000
1 = binector B0001
etc.
P695
Source for selection of "Set speed controller I component" function
*
Selection of binector to control the "Set I component" function
BDS
0 = binector B0000
1 = binector B0001
(G152)
etc.
When the binector selected in P695 switches from log. "0" to log. "1", the I
component of the speed controller is set to the value of the connector
selected in P631.
With this function it is possible, for example, to use the same signal
(binector) to control controller enabling commands and setting of the I
component.
P696
Source for selection of "Stop speed controller I component" function
*
Selection of binector to control the "Stop I component" function
BDS
0 = binector B0000
1 = binector B0001
(G152)
etc.
When the binector selected in P696 changes to the log. "1" state, the I
component of the speed controller is stopped.
P697
Source for selection of enabling of dv/dt injection
*
Selection of binector to control enabling of dv/dt injection (state "1" =
BDS
enable)
(G153)
0 = binector B0000
1 = binector B0001
etc.
P698
Source for selection of enabling command for speed-dependent speed
*
controller PI / P function switchover
BDS
Selection of binector to control enabling of the speed-dependent PI / P
controller switchover function (see also P222)
(G152)
0 = binector B0000
1 = binector B0001
etc.
11.38 Analog inputs (main actual value, main setpoint, selectable inputs)
(see also Section 8, Sheets G113 and G114)
Analog input terminals 4 / 5 (main setpoint)
P700
Signal type of "Main setpoint" analog input
*
0 = Voltage input 0 to ± 10 V
1 = Current input 0 to ± 20 mA
(G113)
2 = Current input 4 to 20 mA
11-74
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
0 to 2
Ind: None
1
FS=0
Type: O2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
6RX1700-0AD76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents