Parameter list
PNU
Description
Timer 8 (0.00 to 600.00s) (output = B9594, inverted: B9595)
U461
Source for input signal and reset signal for timer element 8
(2461)
As for U440
*
S00
(B216)
U462
Time for timer 8
(2462)
S00
(B216)
U463
Mode for timer 8
(2463)
As for U442
*
S00
(B216)
Timer 9 (0.00 to 600.00s) (output = B9596, inverted: B9597)
U464
Source for input signal and reset signal for timer element 9
(2464)
As for U440
*
S00
(B216)
U465
Time for timer 9
(2465)
S00
(B216)
U466
Mode for timer 9
(2466)
As for U442
*
S00
(B216)
Timer 10 (0.00 to 600.00s) (output = B9598, inverted: B9599)
U467
Source for input signal and reset signal for timer element 10
(2467)
As for U440
*
S00
(B216)
U468
Time for timer 10
(2468)
S00
(B216)
U469
Mode for timer 10
(2469)
As for U442
*
S00
(B216)
Binary signal selector switches
The control signal (binector) is selected via index i001 of the parameter.
Control signal = 0: Binector as set in index i002 is applied to the output
Control signal = 1: Binector as set in index i003 is applied to the output
U470
Source for input signals for binary signal selector switch 1
(2470)
(output = B9482)
*
i001
Source for control signal
S00
i002
Source for output signal when control signal = 0
(B216)
i003
Source for output signal when control signal = 1
Settings:
0 = binector B0000
1 = binector B0001
etc.
U471
Source for input signals for binary signal selector switch 2
(2471)
(output = B9483)
*
As for U470
S00
(B216)
11-140
Value range
[Unit]
Steps
All binector numbers
FB 247
1
FB 247 0.00 to 600.00
[s]
0.01
0 to 3
FB 247
1
All binector numbers
FB 248
1
FB 248 0.00 to 600.00
[s]
0.01
0 to 3
FB 248
1
All binector numbers
FB 249
1
FB 249 0.00 to 600.00
[s]
0.01
0 to 3
FB 249
1
All binector numbers
FB 250
1
All binector numbers
FB 251
1
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline