Siemens 6RA7086-6KS22 Operating Instructions Manual page 555

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
r813
Transmit data on G-SST2
When USS protocol (P790=2) is selected:
(G171)
Display of the data to be transmitted via USS interface 2
(G173)
i001:
Display process data word 1
...
i016
Display process data word 16
i017:
Display parameter data word 1
...
i020:
Display parameter data word 4
When peer-to-peer (P790=5) is selected:
Display of the data to be transmitted via peer-to-peer interface 2
i001:
Transmit data word 1
...
i005
Transmit data word 5
i006:
Not used
...
i020
Not used
r814
Receive data on G-SST3
When USS protocol (P800=2) is selected:
(G172)
Display of data received via USS interface 3
(G174)
i001:
Display process data word 1
...
i016
Display process data word 16
i017:
Display parameter data word 1
...
i020:
Display parameter data word 4
When peer-to-peer (P800=5) is selected:
Display of data received via peer-to-peer interface 3
i001:
Receive data word 1
...
i005
Receive data word 5
i006:
Not used
...
i020
Not used
r815
Transmit data on G-SST3
When USS protocol (P800=2) is selected:
(G172)
Display of the data to be transmitted via USS interface 3
(G174)
i001:
Display process data word 1
...
i016
Display process data word 16
i017:
Display parameter data word 1
...
i020:
Display parameter data word 4
When peer-to-peer (P800=5) is selected:
Display of the data to be transmitted via peer-to-peer interface 3
i001:
Transmit data word 1
...
i005
Transmit data word 5
i006:
Not used
...
i020
Not used
Peer-to-peer interfaces: Enable transmission and receipt of telegrams:
If transmission on a peer-to-peer interface is disabled, the associated output drivers are connected to high impedance. If reception is
disabled on a peer-to-peer interface, then the telegram failure monitoring function is deactivated.
P816
Peer-to-peer 2: Source for data reception enabling command
0 = binector B0000
(G173)
1 = binector B0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
Ind: 20
Type: L2
Ind: 20
Type: L2
Ind: 20
Type: L2
All binector numbers
Ind: None
1
FS=1
Type: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P051 = 40
Offline
11-91