Cam Positions - Siemens SINUMERIK Series Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

Suppression of signal inversion
With the following setting, selection of signal inversion for
"plus cam - minus cam > 180 degrees" can be suppressed.
MD10485 SW_CAM_MODE bit 1=1
Figure 8-9
Software cams for modulo rotary axis (plus cam - minus cam > 180 degrees) and suppression of signal
inversion
8.2.3

Cam positions

Setting cam positions
The positions of the plus and minus cams are defined using general setting data:
• SD41500 SW_CAM_MINUS_POS_TAB_1[n]
• SD41501 SW_CAM_PLUS_POS_TAB_1[n]
• SD41502 SW_CAM_MINUS_POS_TAB_2[n]
• SD41503 SW_CAM_PLUS_POS_TAB_2[n]
• SD41504 SW_CAM_MINUS_POS_TAB_3[n]
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
N3: Software cams, position switching cycles - only 840D sl
8.2 Cam signals and cam positions
Position of minus cams 1 - 8
Position of plus cams 1 – 8
Position of minus cams 9 - 16
Position of plus cams 9 - 16
Position of minus cams 17 - 24
543

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 828d

Table of Contents