S7: Memory configuration
14.5 Data lists
Number
Identifier: $MC_
28060
MM_IPO_BUFFER_SIZE
28070
MM_NUM_BLOCKS_IN_PREP
28080
MM_NUM_USER_FRAMES
28081
MM_NUM_BASE_FRAMES
28082
MM_SYSTEM_FRAME_MASK
28083
MM_SYSTEM_DATAFRAME_MASK
28085
MM_LINK_TOA_UNIT
28090
MM_NUM_CC_BLOCK_ELEMENTS
28100
MM_NUM_CC_BLOCK_USER_MEM
28105
MM_NUM_CC_HEAP_MEM
28150
MM_NUM_VDIVAR_ELEMENTS
28160
MM_NUM_LINKVAR_ELEMENTS
28180
MM_MAX_TRACE_DATAPOINTS
28200
MM_NUM_PROTECT_AREA_CHAN
28210
MM_NUM_PROTECT_AREA_ACTIVE
28212
MM_NUM_PROTECT_AREA_CONTOUR
28250
MM_NUM_SYNC_ELEMENTS
28252
MM_NUM_FCTDEF_ELEMENTS
28254
MM_NUM_AC_PARAM
28255
MM_BUFFERED_AC_PARAM
28256
MM_NUM_AC_MARKER
28257
MM_BUFFERED_AC_MARKER
28258
MM_NUM_AC_TIMER
28274
MM_NUM_AC_SYSTEM_PARAM
28276
MM_NUM_AC_SYSTEM_MARKER
28290
MM_SHAPED_TOOLS_ENABLE
28300
MM_PROTOC_USER_ACTIVE
28301
MM_PROTOC_NUM_ETP_OEM_TYP
28302
MM_PROTOC_NUM_ETP_STD_TYP
28400
MM_ABSBLOCK
28402
MM_ABSBLOCK_BUFFER_CONF
28450
MM_TOOL_DATA_CHG_BUFF_SIZE
28500
MM_PREP_TASK_STACK_SIZE
28520
MM_MAX_AXISPOLY_PER_BLOCK
28530
MM_PATH_VELO_SEGMENTS
768
Description
Number of NC blocks in the IPO buffer
Number of blocks for block preparation
Number of settable frames
Number of basic frames (SRAM)
System frames (SRAM)
System frames (SRAM)
Allocation of a TO unit to a channel
Number of block elements for compile cycles
Size of block memory for compile cycles
Heap memory in KB for compile cycle applications
(DRAM)
Number of elements for writing PLC variables
Number of write elements for the NCU link variables
Size of trace data buffer
Number of modules for channel-specific protection
zones
Number of simultaneously active protection zones
Elements for active protection zones (DRAM)
Number of elements for expressions in synchronized
actions
Number of FCTDEF elements
Dimension of $AC_PARAM.
$AC_PARAM[ ] is saved in SRAM.
Dimension of $AC_MARKER
$AC_MARKER[ ] is saved in SRAM.
Number of $AC_TIMER time variables (DRAM)
Number of $AC_SYSTEM_ PARAM for motion-
synchronous actions
Number of $AC_SYSTEM_ MARKER for motion-
synchronous actions
Enable tool-radius compensation for contour tools
Activate logging for a user
Number of ETP OEM event types
Number of ETP standard event types
Activate block display with absolute values
Dimension size of upload buffer
Buffer for tool data changes (DRAM)
Stack size of preparatory task
Maximum number of axis polynomials per block
Number of memory chips for limiting the tool-path
velocity
Function Manual, 03/2013, 6FC5397-1BP40-3BA1