DB10
DBB166
Overwrite screen form for analog NCK outputs
Edge evaluation: No
Signal state 1 or
On signal transition 0 → 1 the previous NCK value is overwritten by the setting value (IS "Setting
edge change 0 → 1
value from PLC for analog NCK outputs"). The previous NCK value which, for example, was
directly set by the part program, is lost.
The analog value specified by the PLC setting value forms the new NCK value.
Signal state 0 or
As the interface signal is only evaluated by the NCK on signal transition 0 → 1 it must be reset to
edge change 1 → 0
"0" again by the PLC user program in the next PLC cycle.
Special cases,
Note:
errors, ....
The PLC interface for the setting value is used both by the overwrite screen form (for signal
transition 0 → 1) and the setting screen form (for signal state 1). Simultaneous activation of the two
screen forms must be avoided via the PLC user program.
Corresponding to ....
DB10 DBB168 (Disable analog NCK outputs)
DB10 DBB167 (Setting screen form of analog NCK outputs)
DB10 DBB170-185 (Setting by PLC of analog NCK outputs)
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS
DB10
DBB167
Setting screen form of analog NCK outputs
Edge evaluation: No
Signal state 1 or
Instead of the NCK value, the PLC value is output at the analog hardware output. The PLC value
edge change 0 → 1
must first be stored in IS "Setting value from PLC for the analog NCK outputs".
The current NCK value is not lost.
Signal state 0 or
The NCK value is output at the analog hardware output.
edge change 1 → 0
Special cases,
Note:
errors, ....
The PLC interface for the setting value is used both by the overwrite screen form (for signal
transition 0 → 1) and the setting screen form (for signal state 1). Simultaneous activation of the two
screen forms must be avoided via the PLC user program.
Corresponding to ....
DB10 DBB168 (Disable analog NCK outputs)
DB10 DBB166 (Overwrite screen form of analog NCK outputs)
DB10 DBB170-185 (Setting by PLC of analog NCK outputs)
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
Signal(s) updated: Cyclic
Signal(s) updated: Cyclic
Z2: NC/PLC interface signals
18.1 Digital and analog NCK I/Os (A4)
841

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 828d

Table of Contents