Parameter Assignment: Link Communication; Configuration - Siemens SINUMERIK Series Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

Time frame of the NC/PLC interface update
The following setting is active during the run-up of all NCUs involved in the link group:
MD18000 $MN_VDI_UPDATE_IN_ONE_IPO_CYCLE = 1
This causes the NC/PLC interface to be read and written completely in just one interpolation
cycle.
2.2.1.4

Parameter assignment: Link communication

NC-specific machine data
Number
Identifier $MN_
MD12510
NCU_LINKNO
MD18780
MM_NCU_LINK_MASK.Bit 0
MD18781
NCU_LINK_CONNECTIONS
MD18782
MM_LINK_NUM_OF_MODULES
2.2.1.5

Configuration

The NC system software supplies specific configurations for each supported combination of
NCU number and position controller cycle of a link group (see section "Parameter
assignment: NC system cycles (Page 83)").
During the system startup, the appropriate configuration will be loaded (as specified by the
values parameterized in the machine data):
● MD18782 $MN_MM_LINK_NUM_OF_MODULES (number of NCUs of the line group))
● MD10061 $MN_POSCTRL_CYCLE_TIME (position controller cycle)
Note
For applications, in which the standard configurations that have been supplied cannot be
used, please contact your local Siemens sales person.
Extended Functions
Function Manual, 03/2013, 6FC5397-1BP40-3BA1
Meaning
Unique numerical identification of the NCU within the link group. The
identifiers must be assigned without any gaps in ascending ordering
starting from 1.
Value range: 1, 2, ... Maximum NCU number
Note:
The NCU to which the value 1 is assigned as NCU identification is the
master NCU of the link group. The parameterization of link axes and
axis containers may only be made with the machine and setting data of
the master NCU.
Activation of the link communication
Number of internal link connections
Note:
It is recommended to retain the default value 0 (determination of the
number by the NC).
Number of NCUs to be connected with one another via NCU link.
B3: Distributed systems - 840D sl only
2.2 NCU link
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840d slSinumerik 828d

Table of Contents