Komatsu PC200-8M0 Shop Manual page 1155

Table of Contents

Advertisement

800 Electrical system
Removal and installation of pump controller assembly
a Connector without connector cover
(1)
2.
Procedure for installing connector cover
1)
Push in right and left sliders (4) as far as
possible.
a Right and left sliders (4) pushed in as
far as possible (Left figure)
2)
Move lever (3) of connector cover (1) from
the upper position to the left position (lock
position) in the figure.
a (B), (C): Claws
a If the sliders and lever are not set as
shown in the following figure, the con-
nector is not disconnected or locked
securely with the lever. Accordingly,
check their positions again.
PC200, 200LC, 220, 220LC-8M0
3)
Set claw (C) to the connector and place
connector cover (1).
a Take care that wiring harness (5) will
not be caught.
4)
Set claw (B) and install connector cover
(1).
5)
Bind connector cover (1) and wiring har-
ness with a new cable tie. (See 1. 1).)
SEN06149-00