Failure code [DWK2KB] Variable Back Press Sol Short Circuit

Action
Failure code
level
L01
DWK2KB
q
Abnormal current flows when pump controller drives variable back pressure solenoid, so pump con-
Detail of failure
troller determines that short circuit exists in variable back pressure solenoid circuit.
q
Stops driving variable back pressure solenoid.
Action of con-
q
Even if cause of failure disappears, machine does not become normal until starting switch is turned
troller
to OFF position.
Problem on
q
Set pressure of back pressure value cannot be changed.
machine
q
Controller's command (ON/OFF) to variable back pressure solenoid can be checked with monitor-
ing function. (If controller sends solenoid ON command, monitoring display is ON even if solenoid
Related infor-
is not switched ON due to short circuit.) (Code: 02301 Solenoid 2)
mation
q
The set pressure of back pressure value becomes low by solenoid ON.
q
Method of reproducing failure code: Turn starting switch to ON position.
No.
Cause
Defective variable back pressure
solenoid valve
1
(internal short circuit or ground
fault)
Open circuit or ground fault in wir-
2
ing harness
Ground fault in wiring harness
3
(contact with ground circuit)
4 Defective pump controller
14
40-305
Failure code [DWK2KB] Variable Back Press Sol Short Circuit
Variable Back Pressure Solenoid Short Circuit
Failure
(Pump controller system)
Procedure, measuring location, criteria and remarks
1. Turn starting switch to OFF position.
2. Disconnect connector V25, and connect T-adapters to male side.
Between V25 (male) (1) and (2)
Between V25 (male) (1) and ground
1. Turn starting switch to OFF position.
2. Disconnect connector C02 and connect T-adapters to female side.
Between C02(female) (85) and each of (115),
(117), (120)
a If no failure is found in checks on cause 2, this check is not required.
1. Turn starting switch to OFF position.
2. Disconnect connectors C02 and V25, and connect T-adapters to either
female side.
Between ground and C02 (female) (85) or
V25 (female)(1)
If no failure is found by above checks, pump controller is defective.
(Since this is an internal defect, troubleshooting cannot be performed.)
305 Troubleshooting by failure code, Part 5
Resistance
Resistance
Resistance
Resistance
PC200, 200LC, 220, 220LC-8M0
20 to 60 z
Min. 1 Mz
20 to 60 z
Min. 1 Mz