SEN06133-00
Failure code [CA155] Chg Air Temp High Speed Derate
Action
Failure code
level
L03
CA155
q
Boost temperature sensed by charge (boost) pressure & temperature sensor exceeds upper limit
Detail of failure
of temperature control.
Action of con-
q
Restricts engine output and allows engine to run.
troller
q
Problem on
Engine output lowers.
q
machine
Engine stops.
q
Boost temperature can be checked with monitoring function.
Related infor-
(Code: 18500 Boost temperature)
mation
q
Method of reproducing failure code: Start engine.
Cause
Lowered cooling performance of
1
aftercooler
Abnormal rise of turbocharger out-
2
let temperature
Defective boost temperature sen-
3
sor
36
40-301
Failure code [CA155] Chg Air Temp High Speed Derate
Charge Air Temperature High Speed Derate
Failure
(Engine controller system)
Procedure, measuring location, criteria and remarks
Aftercooler cooling performance may degrade. Check it for following points:
q
Looseness and damage of fan belt
q
Insufficient cooling air
q
Clogging of aftercooler fins
Outlet temperature of turbocharger may be abnormally high. Check related
parts.
If no failure is found by above checks, boost temperature sensor system may
be defective. Perform troubleshooting for failure codes [CA153] and [CA154].
301 Troubleshooting by failure code, Part 1
PC200, 200LC, 220, 220LC-8M0