SEN06125-00
Cate-
Item
gory
Performance of
hydraulic pump
a As far as possible, bring pump discharge pressure P1 and P2 as close as possible to the average pres-
sure when measuring.
a When measuring with the pump mounted on the machine, if it is impossible to set the engine speed to
the specified speed with the fuel control dial, take the pump discharge amount and the engine speed at
the point of measurement, and use them as a base for calculating the pump discharge amount at the
specified speed.
10
20-100
Applicable model
Measurement condition
• Pump speed (rpm): 2,000rpm
• PC-EPC current value (mA): 440mA
• Discharge pressure of test pump
2
(MPa {kg/cm
}): P1
• Discharge pressure of another
2
pump (MPa {kg/cm
}): P2
• Average discharge pressure
2
(MPa {kg/cm
}): Pp=(P1+P2)÷2
100 Standard service value table
Standard value table for chassis related parts
PC200, 200LC-8M0
Unit
Standard value
Q
l/min
(See graph)
PC200, 200LC, 220, 220LC-8M0
Standard lower limit of
discharge
Q
(See graph)