Komatsu PC200-8M0 Shop Manual page 285

Table of Contents

Advertisement

600 Electrical system
Electrical control system
1)
LS control function
q
Depending on the operation condition of the
actuator, this function changes the pressure
output from the LS-EPC valve to LS valve to
change the change point (LS set differential
pressure (DLS)) of the pump discharge in the
LS valve.
q
By this operation, the start-up time of the pump
discharge is optimized and the composite
operation and fine control performance is
improved.
2)
Cut-off function
This function increases PC-EPC current (J) to
q
reduce the flow rate in the relief state, improv-
ing fuel consumption.
Operating condition for turning on cut-off function
When the average value of the front and rear pressure
sensors is above 27.9 MPa {285 kg/cm
maximizing function off.
The cut-off function does not work, however, while the
machine is travelling in A mode, swing lock switch is in
the "ON" position.
PC200, 200LC, 220, 220LC-8M0
3)
q
Operating condition for turning on 2-
stage relief function
• During travel
• When swing lock switch is turned to
• When boom is lowered
• When power maximizing function is
• When L mode is operated
2
} with the power
2-stage relief function
The relief pressure in the normal work is 34.8
2
MPa {355 kg/cm
}. If the 2-stage relief function
is turned on, however, the relief pressure rises
to about 37.2 MPa {380 kg/cm
tion, the hydraulic force is increased further.
the ON position
turned on
SEN06123-00
2
}. By this opera-
Relief pressure
34.8 MPa
2
{355 kg/cm
}
O
37.2 MPa
2
{380 kg/cm
}
19
10-600